Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.859
Filtrar
Más filtros




Intervalo de año de publicación
1.
Ann Card Anaesth ; 27(1): 68-69, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38722126

RESUMEN

ABSTRACT: The occurrence of pulmonary artery thrombus in association with rheumatic mitral stenosis is a rare complication. Pulmonary artery thrombus formation may worsen pulmonary artery pressures, and this may precipitate acute right heart failure. The possible mechanisms behind pulmonary artery thrombus formation during mitral valve replacement surgery could be acute coagulopathy following surgery, the presence of chronic pulmonary thromboembolism, or chronic atrial fibrillation. We report an unusual case of pulmonary artery thrombus in a patient with rheumatic MS which was diagnosed with transoesophageal echocardiography after MVR.


Asunto(s)
Diagnóstico Tardío , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral , Arteria Pulmonar , Trombosis , Humanos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Arteria Pulmonar/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/cirugía , Femenino , Cardiopatía Reumática/complicaciones , Cardiopatía Reumática/cirugía , Embolia Pulmonar/etiología , Embolia Pulmonar/diagnóstico por imagen , Persona de Mediana Edad
2.
Medicine (Baltimore) ; 103(19): e38022, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38728459

RESUMEN

Warfarin, a widely utilized anticoagulant, is paramount for preventing thromboembolic events in patients with mechanical heart valve replacements. However, its narrow therapeutic index can lead to over-anticoagulation and overdose, resulting in serious health risks. This study examines the efficacy of human prothrombin complex concentrate (PCC) in managing warfarin overdose, in comparison with traditional treatments. A retrospective analysis was conducted on 162 adults who presented with warfarin overdose (INR > 5.0) at a tertiary care hospital between 2016 and 2020. Participants were divided into 2 groups-those treated with PCC (n = 57) and those treated with conventional methods (n = 105), including vitamin K and fresh frozen plasma. The primary outcome was the rate of reaching the target (International Normalized Ratio) INR within 24 hours. Secondary outcomes included transfusion requirements, thromboembolic events, adverse reactions, 30-day mortality, and length of hospital stay. PCC demonstrated significant efficacy, with 89.5% of patients achieving the target INR within 24 hours, compared to 64.8% in the control group (P < .05). The PCC group also had reduced transfusion requirements and a shorter average hospital stay. There was no significant difference in thromboembolic events or adverse reactions between the 2 groups, and the reduced 30-day mortality in the PCC group was not statistically significant. Human prothrombin complex concentrate is associated with rapid reaching the target INR, decreased transfusion needs, and shortened hospitalization, making it a promising option for warfarin overdose management. While the results are encouraging, larger, multicenter, randomized controlled trials are necessary to further validate these findings and optimize PCC administration protocols.


Asunto(s)
Anticoagulantes , Factores de Coagulación Sanguínea , Sobredosis de Droga , Relación Normalizada Internacional , Warfarina , Humanos , Warfarina/efectos adversos , Warfarina/uso terapéutico , Factores de Coagulación Sanguínea/uso terapéutico , Factores de Coagulación Sanguínea/administración & dosificación , Femenino , Masculino , Estudios Retrospectivos , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Persona de Mediana Edad , Sobredosis de Droga/tratamiento farmacológico , Sobredosis de Droga/terapia , Anciano , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Tromboembolia/prevención & control , Adulto , Resultado del Tratamiento , Transfusión Sanguínea/estadística & datos numéricos , Tiempo de Internación/estadística & datos numéricos , Vitamina K/uso terapéutico
3.
Laeknabladid ; 110(5): 247-253, 2024 May.
Artículo en Islandés | MEDLINE | ID: mdl-38713559

RESUMEN

INTRODUCTION: One of the most serious complications of surgical aortic valve replacement (SAVR) is stroke that can result in increased rates of complications, morbidity and mortality postoperatively. The aim of this study was to investigate incidence, risk factors and short-term outcome in a well defined cohort of SAVR-patients. MATERIALS AND METHOD: A retrospective study on 740 consecutive aortic stenosis patients who underwent SAVR in Iceland 2002-2019. Patients with stroke were compared with non-stroke patients; including preoperative risk factors of cardiovascular disease, echocardiogram-results, rate of early postoperative complications other than stroke and 30 day mortality. RESULTS: Mean age was 71 yrs (34% females) with 57% of the patients receiving stented bioprosthesis, 31% a stentless Freestyle®-valve and 12% a mechanical valve. Mean EuroSCORE-II was 3.6, with a maximum preop-gradient of 70 mmHg and an estimated valvular area of 0.73 cm2. Thirteen (1.8%) patients were diagnosed with stroke where hemiplegia (n=9), loss of consciousness (n=3) and/or aphasia (n=4) were the most common presenting symptoms. In 70% of cases the neurological symptoms resolved or disappeared in the first weeks and months after surgery. Only one patient out of 13 died within 30-days (7.7%). Stroke-patients had significantly lower BMI than non-stroke patients, but other risk factors of cardiovascular diseases, intraoperative factors or the rate of other severe postoperative complications than stroke were similar between groups. Total length of stay was 14 days vs. 10 days median, including 2 vs. 1 days in the ICU, in the stroke and non-stroke-groups, respectively. CONCLUSIONS: The rate of stroke after SAVR was low (1.8%) and in line with other similar studies. Although a severe complication, most patients with perioperative stroke survived 30 days postoperatively and in majority of cases neurological symptoms recovered.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Humanos , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Masculino , Anciano , Factores de Riesgo , Estudios Retrospectivos , Islandia/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/etiología , Incidencia , Factores de Tiempo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Anciano de 80 o más Años , Persona de Mediana Edad
4.
Clin Cardiol ; 47(5): e24272, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38742736

RESUMEN

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Mitral , Falla de Prótesis , Humanos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Ecocardiografía Transesofágica , Masculino , Resultado del Tratamiento , Femenino , Anciano , Reoperación
5.
BMC Cardiovasc Disord ; 24(1): 250, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745119

RESUMEN

OBJECTIVES: Prolonged mechanical ventilation (PMV) is a common complication following cardiac surgery linked to unfavorable patient prognosis and increased mortality. This study aimed to search for the factors associated with the occurrence of PMV after valve surgery and to develop a risk prediction model. METHODS: The patient cohort was divided into two groups based on the presence or absence of PMV post-surgery. Comprehensive preoperative and intraoperative clinical data were collected. Univariate and multivariate logistic regression analyses were employed to identify risk factors contributing to the incidence of PMV. Based on the logistic regression results, a clinical nomogram was developed. RESULTS: The study included 550 patients who underwent valve surgery, among whom 62 (11.27%) developed PMV. Multivariate logistic regression analysis revealed that age (odds ratio [OR] = 1.082, 95% confidence interval [CI] = 1.042-1.125; P < 0.000), current smokers (OR = 1.953, 95% CI = 1.007-3.787; P = 0.047), left atrial internal diameter index (OR = 1.04, 95% CI = 1.002-1.081; P = 0.041), red blood cell count (OR = 0.49, 95% CI = 0.275-0.876; P = 0.016), and aortic clamping time (OR = 1.031, 95% CI = 1.005-1.057; P < 0.017) independently influenced the occurrence of PMV. A nomogram was constructed based on these factors. In addition, a receiver operating characteristic (ROC) curve was plotted, with an area under the curve (AUC) of 0.782 and an accuracy of 0.884. CONCLUSION: Age, current smokers, left atrial diameter index, red blood cell count, and aortic clamping time are independent risk factors for PMV in patients undergoing valve surgery. Furthermore, the nomogram based on these factors demonstrates the potential for predicting the risk of PMV in patients following valve surgery.


Asunto(s)
Nomogramas , Valor Predictivo de las Pruebas , Respiración Artificial , Humanos , Factores de Riesgo , Masculino , Femenino , Persona de Mediana Edad , Respiración Artificial/efectos adversos , Factores de Tiempo , Medición de Riesgo , Anciano , Estudios Retrospectivos , Resultado del Tratamiento , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Técnicas de Apoyo para la Decisión , Adulto , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Factores de Edad
6.
Clin Cardiol ; 47(5): e24268, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38741388

RESUMEN

BACKGROUND: Observational studies suggest that valvular surgery can reduce mortality in selected patients with infective endocarditis (IE). However, the benefit of this intervention according to frailty levels remains unclear. Our study aims to assess the effect of valvular surgery according to frailty status in this population. METHODS: We performed a retrospective study using the 2016-2019 National Inpatient Sample database. Adult patients with a primary diagnosis of IE were included. Frailty was assessed using the Hospital Frailty Risk Score. Inverse probability of treatment weighting (IPTW) was used to balance baseline differences between groups. RESULTS: A total of 53,275 patients with IE were included, with 18.3% underwent valvular surgery. The median age was 52 (34-68) years, with 41% females. Overall, 42.7% had low risk of frailty, 53.1% intermediate risk, and 4.2% high risk. After IPTW adjustment, in-hospital mortality was similar both for the entire cohort between valvular and non-valvular surgery groups (3.7% vs. 4.1%, p = .483), and low (1% vs. 0.9%, p = .952) or moderate (5.4% vs. 6%, p = .548) risk of frailty. However, patients at high risk of frailty had significantly lower in-hospital mortality in the valvular surgery group (4.6% vs. 13.9%, p = .016). Renal replacement therapy was similar between groups across frailty status. In contrast, surgery was associated with increased use of mechanical circulatory support and pacemaker implantation. CONCLUSIONS: Our findings suggest that there was no difference in survival between valve surgery and medical management in patients at low/intermediate frailty risk, but not for high-risk individuals.


Asunto(s)
Endocarditis , Fragilidad , Mortalidad Hospitalaria , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Fragilidad/complicaciones , Fragilidad/diagnóstico , Anciano , Endocarditis/cirugía , Endocarditis/mortalidad , Endocarditis/complicaciones , Factores de Riesgo , Medición de Riesgo/métodos , Adulto , Estados Unidos/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/complicaciones , Tasa de Supervivencia/tendencias
7.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38573257

RESUMEN

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Incidencia , Retratamiento
8.
Artículo en Inglés | MEDLINE | ID: mdl-38684422

RESUMEN

PURPOSE: The study aims to assess the effects of dexmedetomidine (Dex) pretreatment on patients during cardiac valve replacement under cardiopulmonary bypass. METHODS: For patients in the Dex group (n = 52), 0.5 µg/kg Dex was given before anesthesia induction, followed by 0.5 µg/kg/h pumping injection before aortic occlusion. For patients in the control group (n = 52), 0.125 ml/kg normal saline was given instead of Dex. RESULTS: The patients in the Dex group had longer time to first dose of rescue propofol than the control group (P = 0.003). The Dex group required less total dosage of propofol than the control group (P = 0.0001). The levels of cardiac troponin I (cTnI), creatine kinase isoenzyme MB (CK-MB), malondialdehyde (MDA), and tumor necrosis factor-α (TNF-α) were lower in the Dex group than the control group at T4, 8 h after the operation (T5), and 24 h after the operation (T6) (P <0.01). The Dex group required less time for mechanical ventilation than the control group (P = 0.003). CONCLUSION: The study suggests that 0.50 µg/kg Dex pretreatment could reduce propofol use and the duration of mechanical ventilation, and confer myocardial protection without increased adverse events during cardiac valve replacement.


Asunto(s)
Biomarcadores , Puente Cardiopulmonar , Dexmedetomidina , Implantación de Prótesis de Válvulas Cardíacas , Propofol , Respiración Artificial , Troponina I , Dexmedetomidina/administración & dosificación , Dexmedetomidina/efectos adversos , Humanos , Puente Cardiopulmonar/efectos adversos , Masculino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Femenino , Factores de Tiempo , Persona de Mediana Edad , Resultado del Tratamiento , Propofol/efectos adversos , Propofol/administración & dosificación , Biomarcadores/sangre , Troponina I/sangre , Forma MB de la Creatina-Quinasa/sangre , Agonistas de Receptores Adrenérgicos alfa 2/efectos adversos , Agonistas de Receptores Adrenérgicos alfa 2/administración & dosificación , Factor de Necrosis Tumoral alfa/sangre , Malondialdehído/sangre , Anciano , Adulto , Anestésicos Intravenosos/efectos adversos , Anestésicos Intravenosos/administración & dosificación , Daño por Reperfusión Miocárdica/prevención & control , Daño por Reperfusión Miocárdica/etiología
9.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38639143

RESUMEN

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Asunto(s)
Técnicas de Ablación , Cateterismo Cardíaco , Cardiomiopatía Hipertrófica , Etanol , Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral , Humanos , Estudios Retrospectivos , Masculino , Etanol/administración & dosificación , Etanol/efectos adversos , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/mortalidad , Cardiomiopatía Hipertrófica/terapia , Cardiomiopatía Hipertrófica/cirugía , Cardiomiopatía Hipertrófica/fisiopatología , Femenino , Resultado del Tratamiento , Técnicas de Ablación/efectos adversos , Técnicas de Ablación/mortalidad , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Persona de Mediana Edad , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Tiempo , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Recuperación de la Función , Anciano de 80 o más Años , Tabiques Cardíacos/diagnóstico por imagen , Tabiques Cardíacos/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad
10.
Catheter Cardiovasc Interv ; 103(6): 1069-1073, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38584521

RESUMEN

An 86-year-old female with history of surgical aortic valve replacement presented with clinical signs of heart failure. Echocardiography revealed a reduction in left ventricular systolic function and severe bioprosthetic aortic valve dysfunction. This is the first reported case of valve-in-valve transcatheter aortic valve replacement with concomitant undermining iatrogenic coronary obstruction with radiofrequency needle procedure in a surgical bioprosthetic valve.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Enfermedad Iatrogénica , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Ablación por Catéter/efectos adversos , Falla de Prótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Lesiones Cardíacas/etiología , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/terapia , Agujas , Función Ventricular Izquierda , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/etiología , Oclusión Coronaria/terapia , Oclusión Coronaria/fisiopatología , Angiografía Coronaria
11.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38597297

RESUMEN

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Asunto(s)
Cateterismo Cardíaco , Análisis de Elementos Finitos , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Modelos Cardiovasculares , Modelación Específica para el Paciente , Diseño de Prótesis , Válvula Pulmonar , Humanos , Válvula Pulmonar/fisiopatología , Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Medición de Riesgo , Adolescente , Resultado del Tratamiento , Factores de Riesgo , Masculino , Niño , Estudios Retrospectivos , Femenino , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Adulto Joven , Valor Predictivo de las Pruebas , Hemodinámica , Stents , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Obstrucción del Flujo Ventricular Externo/fisiopatología , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Toma de Decisiones Clínicas , Adulto
12.
J Cardiothorac Surg ; 19(1): 219, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627820

RESUMEN

OBJECTIVES: Thrombocytopenia following Perceval aortic valve replacement has been described previously with variable outcome. Studies have lacked a robust analysis of platelet fluctuation and factors affecting it. We aimed to statistically describe the trend in thrombocyte variability as compared with conventional aortic valve replacement, and to assess predictors as well as impact on associated outcomes. METHODS: One hundred consecutive patients with first-time Perceval were retrospectively compared to 219 patients after Perimount Magna Ease valve replacement. The primary outcome was the serial thrombocyte count on day 0-6. Generalized estimating equations were used to analyse the data using fixed-effect models: for the effect of the post-operative day on platelet count, and random-effect models estimating both time-variant (platelets) and time in-variant variables (valve type, age, LV function, pre-op platelet level). RESULTS: Perceval patients were older (72 ± 1 vs 68 ± 1 years, p < 0.01) with higher NYHA status (3(2-3) vs 2(1-2), p < 0.001). Mean platelet count in the sutureless group was lowest on day 2 (91.9 ± 31.6 vs 121.7 ± 53.8 × 103 µl-1), and lower on day 4 (97.9 ± 44) and 6 (110.6 ± 61) compared to the conventional group (157.2 ± 60 and 181.7 ± 79) but did not result in a higher number of transfusions, bleeding or longer hospital stay (p > 0.05). Reduced platelet count was a strong predictor of red cell transfusion in the conventional (p = 0.016), but not in the sutureless group (p = 0.457). Age (Coef -1.025, 95%CI-1.649--0.401, p < 0.001) and CPB-time (Coef 0.186, 95%CI-0.371--0.001, p = 0.048) were predictors for lower platelet levels. CONCLUSION: Considering the older patient profile treated with Perceval, postoperative thrombocytopenia does not impact on outcome in terms of transfusions, complications or hospital stay.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombocitopenia , Humanos , Válvula Aórtica/cirugía , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Bioprótesis/efectos adversos , Diseño de Prótesis , Prótesis Valvulares Cardíacas/efectos adversos , Trombocitopenia/etiología , Factores de Riesgo , Progresión de la Enfermedad
15.
JACC Cardiovasc Interv ; 17(8): 1073-1075, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38658125
17.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38569760

RESUMEN

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Adulto , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Sistema de Registros , Diseño de Prótesis , Estudios Retrospectivos
18.
JACC Cardiovasc Interv ; 17(8): 1060-1062, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38573255
20.
Circ Cardiovasc Imaging ; 17(4): e016435, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38626096

RESUMEN

Heart valve replacement has steadily increased over the past decades due to improved surgical mortality, an aging population, and the increasing use of transcatheter valve technology. With these developments, prosthetic valve complications, including prosthetic valve endocarditis, are increasingly encountered. In this review, we aim to characterize the manifestations of prosthetic valve endocarditis using representative case studies from our institution to highlight the advances and contributions of modern multimodality imaging techniques.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Humanos , Anciano , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/terapia , Prótesis Valvulares Cardíacas/efectos adversos , Endocarditis/diagnóstico por imagen , Endocarditis/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Imagen Multimodal , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA